- 800G in one OSFP port, as one 800G link or two 400G links
- Reach: 50 m (OM4), 500 m, 2 km and 10 km (single-mode)
- Dual MPO-12 or dual duplex LC connectors
- Coding for NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, generic or custom
- Finned top for high-density switch ports
- OSFP MSA, CMIS 5.x host management
Engineered to Outperform
Delivered with Certainty
Procurement Made Simple
Rapid Deployment Ready
Ready To Scale
Compliance Assured
OSFP 800G transceivers have 8 electrical lanes at 100G PAM4. All modules in the range use the same finned OSFP body. Select the module for the link length, from 50 m on multimode fiber to 10 km on single-mode fiber.
DR8 and 2×DR4 operate over 500 m on two MPO-12 connectors. DR8 is one 800G link. 2×DR4 is two independent 400G links. DR8+ (2 km) and DR8++ (10 km) use the same two MPO-12 connectors. 2×FR4 (2 km) and 2×LR4 (10 km) are twin-port modules with two duplex LC connectors. VR8 operates over 50 m of OM4 multimode fiber. All modules operate from 0 °C to +70 °C.
Coding: each module is listed with NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) and generic (-CG) coding. Custom coding is available on request. The coding changes only the EEPROM identity.
| Electrical | |
| Host Interface | OSFP (8 lanes × 100G PAM4) |
| Power Consumption | DR8+: <16 W DR8++: <18.5 W 2×FR4: <16 W VR8: <13.5 W Other variants: see datasheet |
| Optical | |
| Wavelengths | DR8, 2×DR4, DR8+, DR8++: 1310 nm 2×FR4, 2×LR4: CWDM4 (1271 / 1291 / 1311 / 1331 nm) VR8: 850 nm VCSEL |
| Reach | VR8: 50 m OM4 / 30 m OM3 DR8, 2×DR4: 500 m SMF DR8+, 2×FR4: 2 km SMF DR8++, 2×LR4: 10 km SMF |
| Fiber Type | OS2 single-mode (all except VR8) OM3 / OM4 multimode (VR8) |
| Connectors | Dual MPO-12 (DR8, 2×DR4, DR8+, DR8++) Dual MPO-12 APC (VR8) Dual duplex LC (2×FR4, 2×LR4) |
| Media Standards | 800GBASE-DR8 / 2×400GBASE-DR4 (IEEE 802.3df) 2×400GBASE-FR4 (IEEE 802.3cu) 2×400G-LR4-10 (100G Lambda MSA) VR8: 2×400GBASE-SR4 (IEEE 802.3db) |
| Protocol Support | |
| Ethernet | 800 GbE, or 2 × 400 GbE (twin-port variants) |
| Coding & Compatibility | |
| Standard Codings | NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), generic (-CG). The optical module is the same for each coding. Only the EEPROM identity is different. |
| Custom Coding | Available on request for other switch vendors. |
| Environmental | |
| Operating Temperature | 0 °C to +70 °C (Commercial) |
| Storage Temperature | -40 °C to +85 °C |
| MSA Compliance | OSFP MSA Rev 5.0+ |
| Compliance | |
| Standards | IEEE 802.3cu / 802.3db / 802.3df, 100G Lambda MSA, OSFP MSA, CMIS 5.x, RoHS3 |
| RoHS Compliant | Yes |
| OSFP 800G DR8 (Dual MPO-12, single-mode) | |
| Part Number | Description |
| PO-OS-800GE-DR8-2MPO-FN-CN | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-DR8-2MPO-FN-CC | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Cisco-coded |
| PO-OS-800GE-DR8-2MPO-FN-CJ | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Juniper-coded |
| PO-OS-800GE-DR8-2MPO-FN-CA | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Arista-coded |
| PO-OS-800GE-DR8-2MPO-FN-CH | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-DR8-2MPO-FN-CD | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Dell-coded |
| PO-OS-800GE-DR8-2MPO-FN-CF | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-DR8-2MPO-FN-CG | OSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, generic (uncoded) |
| OSFP 800G 2×DR4 Twin-Port (Dual MPO-12, single-mode) | |
| Part Number | Description |
| PO-OS-800GE-2DR4-2MPO-FN-CN | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CC | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Cisco-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CJ | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Juniper-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CA | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Arista-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CH | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CD | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Dell-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CF | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-2DR4-2MPO-FN-CG | OSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, generic (uncoded) |
| OSFP 800G DR8+ Extended Reach (Dual MPO-12, single-mode) | |
| Part Number | Description |
| PO-OS-800GE-DR8K2-2MPO-FN-CN | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CC | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Cisco-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CJ | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Juniper-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CA | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Arista-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CH | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CD | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Dell-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CF | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-DR8K2-2MPO-FN-CG | OSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, generic (uncoded) |
| OSFP 800G DR8++ Long Reach (Dual MPO-12, single-mode) | |
| Part Number | Description |
| PO-OS-800GE-DR8K10-2MPO-FN-CN | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CC | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Cisco-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CJ | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Juniper-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CA | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Arista-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CH | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CD | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Dell-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CF | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-DR8K10-2MPO-FN-CG | OSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, generic (uncoded) |
| OSFP 800G 2×FR4 CWDM4 Twin-Port (Dual Duplex LC, single-mode) | |
| Part Number | Description |
| PO-OS-800GE-2FR4-2LC-CN | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-2FR4-2LC-CC | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Cisco-coded |
| PO-OS-800GE-2FR4-2LC-CJ | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Juniper-coded |
| PO-OS-800GE-2FR4-2LC-CA | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Arista-coded |
| PO-OS-800GE-2FR4-2LC-CH | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-2FR4-2LC-CD | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Dell-coded |
| PO-OS-800GE-2FR4-2LC-CF | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-2FR4-2LC-CG | OSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, generic (uncoded) |
| OSFP 800G 2×LR4 Twin-Port (Dual Duplex LC, single-mode) | |
| Part Number | Description |
| PO-OS-800GE-2LR4-2LC-FN-CN | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-2LR4-2LC-FN-CC | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Cisco-coded |
| PO-OS-800GE-2LR4-2LC-FN-CJ | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Juniper-coded |
| PO-OS-800GE-2LR4-2LC-FN-CA | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Arista-coded |
| PO-OS-800GE-2LR4-2LC-FN-CH | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-2LR4-2LC-FN-CD | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Dell-coded |
| PO-OS-800GE-2LR4-2LC-FN-CF | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-2LR4-2LC-FN-CG | OSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, generic (uncoded) |
| OSFP 800G VR8 Multimode (2×400G SR4, Dual MPO-12 APC) | |
| Part Number | Description |
| PO-OS-800GE-VR8-2MPO-CN | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, NVIDIA-coded |
| PO-OS-800GE-VR8-2MPO-CC | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Cisco-coded |
| PO-OS-800GE-VR8-2MPO-CJ | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Juniper-coded |
| PO-OS-800GE-VR8-2MPO-CA | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Arista-coded |
| PO-OS-800GE-VR8-2MPO-CH | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, HPE / Aruba-coded |
| PO-OS-800GE-VR8-2MPO-CD | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Dell-coded |
| PO-OS-800GE-VR8-2MPO-CF | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Fortinet-coded |
| PO-OS-800GE-VR8-2MPO-CG | OSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, generic (uncoded) |
















